EasyDigital - implant dentistry made simple, easy and affordable Discover more
Wide 1375x970

Neoss ProActive® Wide

Wide implants can provide additional means of anchorage in challenging cases, such as extraction sites, sinus floor elevations and compromised bone, when compared to narrow implants. They can also act as rescue implants when initial stability is not achieved with a narrower implant.

Why Neoss ProActive® Wide

Ø6.0 Implant body

Prosthetic platform - The prosthetic platform measures Ø4.0 with six internal rotational positions.

Flange - Straight flange. Compatible with Wide Emergence Abutment.

Mid-section - Slightly tapered to achieve compression and increase stability in poor bone quality.

Lower section - Tapered section is 4 - 5 mm long on all lengths.

Apex - Narrow and spherical.

Ø6.5 Implant body

Prosthetic platform - The prosthetic platform measures Ø4.0 with six internal rotational positions.

Flange - Tapered flange to achieve increased cortical stability.

Mid-section - Slightly tapered to achieve compression and increase stability in poor bone quality.

Lower section - Tapered section is 3 - 4 mm long on all lengths.

Apex - Rounded. Designed to be more forgiving in sinus lift situations

Neoss ProActive, a super hydrophilic surface

Neoss ProActive® Implants have a super hydrophilic surface demonstrated by an immeasurable low contact angle. The Neoss ProActive® surface has demonstrated faster and stronger osseointegration (when compared to blasted surfaces).1

The Neoss ProActive surface

The Neoss ProActive surface has demonstrated faster and stronger osseointegration compared to a blasted implant surface in in-vivo studies.1

The surface is achieved by subjecting the commercially pure titanium implant to a multistage blasting, etching, and super hydrophilicity treatment, which enables the implant to achieve a high level of wettability. As a result, Neoss ProActive Implants have a super hydrophilic surface.

The rougher surface on the threaded implant body stimulates bone to form more rapidly and with greater strength at the implant surface, allowing for earlier loading protocols.

The Neoss ProActive production process and packaging minimizes the already low carbon content on the surface, maximizing surface energy.

Group 53

Receive the latest news from Neoss, live webinars, new products, and much more!

Rectangle 130 (2) (1)
Contact us about

Neoss ProActive® Wide

Notes

1. Gottlow J & Sennerby L, 2010. ‘Influence of surface and implant design on stability of five commercial titanium implants. A Biomedical study in the rabbit’, AO Meeting, Post 83
2. Renouard F, Nisand D. Short implants in the severely resorbed maxilla: a 2-year retrospective clinical study. Clin Implant Dent Relat Res. 2005;7 Suppl 1:S104–10. 3. Meredith N; A review of implant design, geometry and placement. Appl Osseointgrated Res 2008 6 pp 6–12.